Click photo to enlarge
 
 
Slope
The minimum recommended slope for the PBR Panel is 1:12.
Substrate
PBR Panel can be used over open structure framing and can also be used over solid substrates. It isrecommended to be installed over 5/8” plywood decking with a 30 pound felt moisture barrier.
Coverage
The PBR Panel is offered in a 36” coverage panel with a 1 ¼” rib height.
Length
Minimum panel length offered is 36” with a maximum panel length of 35’ on delivery. Longer lengths available with prior coordination from outsourced hauling.
Availability
The PBR Panel is available in 26 and 24 gauge.
Performance Test
UL 580-94 / UL 1897-98 in accordance with Florida Building Code 2004.
Fastening System
Exposed Fastener # 10 – 12 x 6 x 1 ½” HWH
Materials
Steel Grade 80/D per ASTM A-792
Color Options
Galvalume – Siliconized Polyester – Kynar Available Special Order
Click photo to enlarge
 
 
Slope
The minimum recommended slope for the M Panel is 1:12.
Substrate
M Panel can be used over open structure framing and can also be used over solid substrates. It is
recommended to be installed over 5/8” plywood decking with a 30 pound felt moisture barrier.
Coverage
The M Panel is offered in a 36” coverage panel with a ¾” rib height.
Length
Minimum panel length offered is 40” with a maximum panel length of 35’ on delivery. Longer lengths
available with prior coordination from outsourced hauling.
Availability
The M Panel is available in 26 and 24 gauge.
Performance Test
UL 580-94 / UL 1897-98 in accordance with Florida Building Code 2004.
Fastening System
Exposed Fastener # 10 – 12 x 6 x 1 ½” HWH
Materials
Steel Grade 80/D per ASTM A-792
Color Options
Galvalume – Siliconized Polyester – Kynar Available Special Order
Click photo to enlarge
 
 
Slope
The minimum recommended slope for the Classic Rib Panel is 2:12.
Substrate
Classic Rib can be used over open structure framing and can also be used over solid substrates. It is
recommended to be installed over 5/8” plywood decking with a 30 pound felt moisture barrier.
Coverage
The Classic Rib panel is offered in a 36” coverage panel with a ¾” rib height.
Length
Minimum panel length offered is 36” with a maximum panel length of 35’ on delivery. Longer lengths
available with prior coordination from outsourced hauling.
Availability
The Classic Rib panel is available in 29, 26 and 24 gauge.
Performance Test
UL 580-94 / UL 1897-98 in accordance with Florida Building Code 2004.
Fastening System
Exposed Fastener # 10 – 12 x 6 x 1 ½” HWH
Materials
Steel Grade 50/E per ASTM A-792
Steel Grade 80/D per ASTM A-792
Color Options
Galvalume – Siliconized Polyester – Kynar Available Special Order
Click photo to enlarge
 
 
Slope
The minimum recommended slope for the Cor-Span panel is 1:12.
Substrate
Cor-Span can be used over open structure framing and can also be used over solid substrates. It is
recommended to be installed over 5/8” plywood decking with a 30 pound felt moisture barrier.
Coverage
The Cor-Span panel is offered in a 32” coverage panel with a 7/8” rib height.
Length
Minimum panel length offered is 40” with a maximum panel length of 35’ on delivery. Longer lengths
available with prior coordination from outsourced hauling.
Availability
The Cor-Span panel is available in 26 and 24 gauge.
Performance Test
UL 580-94 / UL 1897-98 in accordance with Florida Building Code 2004.
Fastening System
Exposed Fastener # 10 – 12 x 6 x 2” HWH
Materials
Steel Grade 80/D per ASTM A-792
Color Options
Galvalume – Siliconized Polyester – Kynar Available Special Order
Click photo to enlarge
 
 
Slope
The minimum recommended slope for the 5-V Crimp panel is 3:12.
Substrate
5-V Crimp should only be used over solid substrates. It is recommended to be installed over 5/8” plywood decking with a 30 pound felt moisture barrier.
Coverage
The 5-V Crimp panel is offered in a 24” coverage panel with a 1/2” rib height.
Length
Minimum panel length offered is 24” with a maximum panel length of 35’ on delivery. Longer lengths
available with prior coordination from outsourced hauling.
Availability
The 5-V Crimp panel is available in 26 and 24 gauge.
Performance Test
UL 580-94 / UL 1897-98 in accordance with Florida Building Code 2004.
Fastening System
Exposed Fastener # 10 – 12 x 6 x 1 ½” HWH
Materials
Steel Grade 50/E per ASTM A-792
Steel Grade 80/D per ASTM A-792
Color Options
Galvalume – Siliconized Polyester Available Special Order
 
COLOR CHART
Download pdf here
 

 

 

 

Metal Roofing Center & Supply
9392 Hard Drive
Foley, AL 36535
251.970.3320
 

© Copyright 2009 Metal Roofing Center & Supply